3D Dynamic Focus System-FR50-C

Short Description:

High-end industry application

Support wavelength:10640nm、10200nm、9400nm


Product Detail

Product Tags

34

Smaller spot size

II-IV optical components,small light loss with thinner spot 0.14mm@200x200mm@10640nm.

Optional water cooling design, it can be applied to high-temperature drift requirements.

Automatic focal adjust option for choose, finish work field and focal length switch through software.

Standard with XY2-100 protocol, optional NCL2 protocol. When NCL2 is selected, real-time feedback of 27 key data points across four categories of scanhead status is available.

35

Flexible large field processing

Through the 3rd axis control to reach larger work field.

36

Smaller spot size

The minimum spot size could be 0.14mm. Even if under 800*800mm large field, the spot size is only 0.4mm, the thermal impact is little.

37
38

Product Technical Information

Items Input Voltage(vdc) ±24V
Current(A) 10A(Rms)  19A(Peak)
Protocol XY2‑100/NCL2
Weight (KG) 28
Size(mm) 528×255×260
Cooling
Condition
Cooling Media Distilled or de‑ionized water plus corrosion inhibitor
Temperature(℃) 22‑28
Recommended cooling pressure 2‑3
Recommended flow rate(l/min) 4‑6
Optical
specifications
Aperture Size(mm) 50
Input beam diameter(mm) 13.5
galvanometer
specifications
Scan Angle(°) ±11
Repeatability(μrad) 5
Max.Gain Drift(ppm/k) 100
Max.Offset Drift(μrad/k) 30
Long‑term drift over 8h(mrad) ≤0.2
Tracking Error(ms) ≤0.68
1% step response(ms) 1.7
Working
Field
Working Field(mm) 200×200 300×300 400×400 500×500 600×600 800×800 1000×1000
The Min.Spot Diameter@1/e²(mm) 0.14 0.18 0.21 0.25 0.3 0.4 0.51
Focal length(mm) 235 335 435 535 645 905 1185

Note: The Z-axis zoom range varies depending on different applications and is specifically determined by the process requirements.

Mechanical Drawing

39

  • Previous:
  • Next:

  • Write your message here and send it to us